Specifications, one row per model (no merged cells)

ProductModelRated capacityNominal voltageVoltage rangeNominal energyDimensions (W×D×H)WeightCell configurationAmbient temperature (operating)Ambient humidityMax. charge/discharge current (continuous)Max. charge/discharge current (short-time)Major built-in functionsStrengthRapid chargeExterior caseMax. modules in seriesMax. system voltage
Type1-23 (2 in Parallel × 12 in Series)FM01202CCB02A45 Ah (25°C, 0.2C discharge)27.6 V18–32.4 V1242 Wh190×361×125 mm (Protrusions excluded)15 kg2 in Parallel × 12 in Series (24 pcs of 23Ah cells)-30–45 CEL%RH (no condensation)160 A (Not over 55°C at cell temperature, at 25°C ambient)350 A (rush current; Not over 55°C at cell temperature, at 25°C ambient)Cell voltage measurement, module temperature measurement, cell balancing*1, communication (Function to even differences in voltage among cells connected in series)Vibration Resistance
Type1-23 (2 in Parallel × 11 in Series)FM01102CCB02A45 Ah (25°C, 0.2C discharge)25.3 V16.5–29.7 V1138 Wh190×361×125 mm (Protrusions excluded)14 kg2 in Parallel × 11 in Series (22 pcs of 23Ah cells)-30–45 CEL%RH (no condensation)160 A (Not over 55°C at cell temperature, at 25°C ambient)350 A (rush current; Not over 55°C at cell temperature, at 25°C ambient)Cell voltage measurement, module temperature measurement, cell balancing*1, communication (Function to even differences in voltage among cells connected in series)Vibration Resistance
Type3-10FM01202CKA01A20 Ah (25°C, 0.2C discharge)28.8 V21.6–32.4 V576 Wh190×361×125 mm (Protrusions excluded)14 kg2 in Parallel × 12 in Series (24 pcs of 10Ah cells)-20–45 CEL%RH (no condensation)160 A (Not over 55°C at cell temperature, at 25°C ambient)500 A (10 s; Not over 55°C at cell temperature, at 25°C ambient)Cell voltage measurement, module temperature measurement, cell balancing*1, communication (Function to even differences in voltage among cells connected in series)
Type3-20FM01202CCA04A40 Ah (25°C, 0.2C discharge)27.6 V18–32.4 V1104 Wh190×361×125 mm (Protrusions excluded)14 kg2 in Parallel × 12 in Series (24 pcs of 20Ah cells)-30–45 CEL%RH (no condensation)160 A (Not over 55°C at cell temperature, at 25°C ambient)350 A (rush current; Not over 55°C at cell temperature, at 25°C ambient)Cell voltage measurement, module temperature measurement, cell balancing*1, communication (Function to even differences in voltage among cells connected in series)approx. 80% of capacity in 12 minutes (Type3-20 module)flame-retardant resin37 modules (1-23 modules up to 750 V, 24-28 up to 910 V, 29-37 up to 1200 V system voltage)1200 V (with 29 to 37 modules in series and SDC-1500)
Type3-20HPFM01202CCE01A39 Ah (25°C, 0.2C discharge)27.6 V18–32.4 V1076 Wh190×361×125 mm (Protrusions excluded)15 kg2 in Parallel × 12 in Series (24 pcs of 20Ah-HP cells)-30–45 CEL%RH (no condensation)160 A (Not over 60°C at cell temperature, at 25°C ambient)500 A (10 s; Not over 60°C at cell temperature, at 25°C ambient)Cell voltage measurement, module temperature measurement, cell balancing*1, communication (Function to even differences in voltage among cells connected in series)37 modules (1-23 modules up to 750 V, 24-28 up to 910 V, 29-37 up to 1200 V system voltage)1200 V (with 29 to 37 modules in series and SDC-1500)
Type3-23 (2 in Parallel × 12 in Series)FM01202CCB01A45 Ah (25°C, 0.2C discharge)27.6 V18–32.4 V1242 Wh190×361×125 mm (Protrusions excluded)15 kg2 in Parallel × 12 in Series (24 pcs of 23Ah cells)-30–45 CEL%RH (no condensation)160 A (Not over 55°C at cell temperature, at 25°C ambient)350 A (rush current; Not over 55°C at cell temperature, at 25°C ambient)Cell voltage measurement, module temperature measurement, cell balancing*1, communication (Function to even differences in voltage among cells connected in series)37 modules (1-23 modules up to 750 V, 24-28 up to 910 V, 29-37 up to 1200 V system voltage)1200 V (with 29 to 37 modules in series and SDC-1500)
Type3-23 (2 in Parallel × 11 in Series)FM01102CCB01A45 Ah (25°C, 0.2C discharge)25.3 V16.5–29.7 V1138 Wh190×361×125 mm (Protrusions excluded)14 kg2 in Parallel × 11 in Series (22 pcs of 23Ah cells)-30–45 CEL%RH (no condensation)160 A (Not over 55°C at cell temperature, at 25°C ambient)350 A (rush current; Not over 55°C at cell temperature, at 25°C ambient)Cell voltage measurement, module temperature measurement, cell balancing*1, communication (Function to even differences in voltage among cells connected in series)
Type3-26FM01202CCF01A51.1 Ah (25°C, 0.2C discharge)27.6 V18–33 V1410 Wh190×361×125 mm (Protrusions excluded)15 kg2 in Parallel × 12 in Series (24 pcs of 26Ah cells)-30–45 CEL%RH (no condensation)160 A (Not over 60°C at cell temperature, at 25°C ambient)350 A (rush current; Not over 60°C at cell temperature, at 25°C ambient)Cell voltage measurement, module temperature measurement, cell balancing*1, communication (Function to even differences in voltage among cells connected in series)37 modules (1-23 modules up to 750 V, 24-28 up to 910 V, 29-37 up to 1200 V system voltage)1200 V (with 29 to 37 modules in series and SDC-1500)
2P12S module Type4-23FM01202CCB04A45 Ah (25°C, 0.2C discharge)27.6 V18–32.4 V1242 Wh204×395×135 mm (Protrusions excluded)16.5 kg2 in Parallel × 12 in Series (24 pcs of 23Ah cells)-30–50 CEL%RH (no condensation)160 A (or more (with water-cooling plate or forced-air cooling); Not over 55°C at cell temperature, at 25°C ambient; Value at the time of combination of water cooling plate or forced-air cooling. (The cooling system shall be arranged by the customer.))350 A (rush current; or more (with water-cooling plate or forced-air cooling); Not over 55°C at cell temperature, at 25°C ambient; Value at the time of combination of water cooling plate or forced-air cooling. (The cooling system shall be arranged by the customer.))Cell voltage measurement, module temperature measurement, cell balancing*1, communication (Function to even differences in voltage among cells connected in series)High Heat Dissipation

Features

2P12S modules provide enhanced environmental robustness, making them suitable for various applications.
These modules operate at temperatures as low as -30°C and at altitudes of up to 2000 m while providing high withstand voltage and vibration tolerance.

Low risk of fire or explosion

Cycle life of 20,000 times or more

Usable even at -30℃

Large current for both input and output

Rapidly charges to about 80% of the capacity in 12 minutes

Available SOC range of 0 to 100%

* SOC : State of Charge

Application Example 

Lineup

Standard Module
For industrial devices and stationary systems

Type3-10 / Type3-20HP / Type3-20 / Type3-23* / Type3-26

A versatile battery module available in multiple capacities, commonly used in power storage and marine vessel applications.

Module for Motive Applications
For motive applications, industrial devices and stationary systems

Type1-23*

A battery module with enhanced vibration resistance, suitable for motive applications.

High Heat Dissipation Module
For motive applications, industrial devices and stationary systems

Type4-23

A battery equipped with an aluminum base plate, providing improved heat dissipation performance.

*2P11S modules is also available.

Components

Toshiba offers various components necessary to build battery systems such as BMUs, connectors, and sensors.

Characteristics

Discharge rate characteristics

Charge rate characteristics

* The above characteristics are for Type 3-20.
* Specifications shown herein are not guaranteed values and are subject to change without notice. Battery performance depends on conditions of use.
* Product specifications are subject to change without notice.

Product Specifications

Recommended application For industrial devices and stationary systems
Strength  Strength
Product name  Type3-10 Type3-20HP Type3-20 Type3-23
(2 in Parallel × 11 in Series)
Type3-23
(2 in Parallel × 12 in Series)
Type3-26
Model FM01202CKA01A FM01202CCE01A FM01202CCA04A FM01102CCB01A FM01202CCB01A FM01202CCF01A
Cell configuration 2 in Parallel × 12 in Series
(24 pcs of 10Ah cells)
2 in Parallel × 12 in Series
(24 pcs of 20Ah-HP cells)
2 in Parallel × 12 in Series
(24 pcs of 20Ah cells)
2 in Parallel × 11 in Series
(22 pcs of 23Ah cells)
2 in Parallel × 12 in Series
(24 pcs of 23Ah cells)
2 in Parallel × 12 in Series
(24 pcs of 26Ah cells)
Rated capacity 20 Ah (25°C, 0.2C discharge) 39 Ah (25°C, 0.2C discharge) 40 Ah (25°C, 0.2C discharge) 45 Ah (25°C, 0.2C discharge) 45 Ah (25°C, 0.2C discharge) 51.1 Ah (25°C, 0.2C discharge)
Nominal energy 576Wh 1076Wh 1104Wh 1138Wh 1242Wh 1410Wh
Nominal voltage 28.8V DC 27.6V DC 27.6V DC 25.3V DC 27.6V DC 27.6V DC
Voltage range 21.6 to 32.4V DC 18.0 to 32.4V DC 18.0 to 32.4V DC 16.5 to 29.7V DC 18.0 to 32.4V DC 18.0 to 33.0V DC
Ambient temperature -20 to 45℃ -30 to 45℃ -30 to 45℃ -30 to 45℃ -30 to 45℃ -30 to 45℃
Ambient humidity 85%RH or less (no condensation) 90%RH or less
(no condensation)
Dimensions W190×D361×H125mm (Protrusions excluded)
Mass Approx. 14kg Approx. 15kg Approx. 14kg Approx. 14kg Approx. 15kg Approx. 15kg
Maximum charge/
discharge current
160A (continuous),  400A (180 s), 500A (10 s),
(Not over 55°C at cell temperature, at 25°C ambient)
160A (continuous), 500A(10 s),
(Not over 60°C at cell temperature, at 25°C ambient)
160A (continuous), 350A (rush current),
(Not over 55°C at cell temperature, at 25°C ambient)
160A (continuous), 350A (rush current),
(Not over 55°C at cell temperature, at 25°C ambient)
160A (continuous), 350A (rush current),
(Not over 55°C at cell temperature, at 25°C ambient)
160A (continuous),
350A (rush current),
(Not over 60°C at cell temperature, at 25°C ambient)
Major built-in
functions
Cell voltage measurement, module temperature measurement, cell balancing*1, communication
Standards Safety*4 - UL 1973 (Recognized)*5 UL 1973 (Recognized)*5
JIS C 8715-2: 2012
IEC62619
UL 1973 (Recognized) *5 UL 1973 (Recognized)*5
JIS C 8715-2: 2012
IEC62619
JIS C 8715-2: 2019
Ship
(Class NK)
- Type approval certificate for lithium-ion battery system*5 Type approval certificate for lithium-ion battery system*5 Type approval certificate for lithium-ion battery system*5 Type approval certificate for lithium-ion battery system*5 Type approval certificate for lithium-ion battery system*5
Recommended application For motive application*2, industrial devices, and stationary systems
Strength Vibration Resistance High Heat Dissipation
Product name Type1-23
(2 in Parallel × 11 in Series)
Type1-23
(2 in Parallel × 12 in Series)
2P12S module
Type4-23
Model FM01102CCB02A FM01202CCB02A FM01202CCB04A
Cell configuration 2 in Parallel × 11 in Series
(22 pcs of 23Ah cells)
2 in Parallel × 12 in Series
(24 pcs of 23Ah cells)
2 in Parallel × 12 in Series
(24 pcs of 23Ah cells)
Rated capacity 45Ah (25°C, 0.2C discharge) 45Ah (25°C, 0.2C discharge) 45Ah (25°C, 0.2C discharge)
Nominal energy 1138Wh 1242Wh 1242Wh
Nominal voltage 25.3V DC 27.6V DC 27.6V DC
Voltage range 16.5 to 29.7V DC 18.0 to 32.4V DC 18.0 to 32.4V DC
Ambient temperature -30 to 45°C -30 to 50°C
Ambient humidity 85%RH or less (no condensation) 90%RH or less
(no condensation)
Dimensions W190×D361×H125mm (Protrusions excluded) W204×D395×H135mm (Protrusions excluded)
Mass Approx. 14kg Approx. 15kg Approx. 16.5kg
Maximum charge/
discharge current
160A (continuous), 350A (rush current),
(Not over 55°C at cell temperature, at 25°C ambient)
160A (continuous), 350A (rush current),
(Not over 55°C at cell temperature, at 25°C ambient)
Over*3 160A (continuous),
Over*3 350A (rush current),
(Not over 55°C at cell temperature, at 25°C ambient)
Major built-in
functions
Cell voltage measurement, module temperature measurement, cell balancing*1, communication
Standards Safety*4 UL 1973 (Recognized)*5
JIS C 8715-2: 2012
IEC62619
UL 1973 (Recognized)*5
Ship
(Class NK)
Type approval certificate for lithium-ion battery system*5 Type approval certificate for lithium-ion battery system*5

 

*1 Function to even differences in voltage among cells connected in series
*2 Motive applications as specified in IEC 62619:2022.
*3 Value at the time of combination of water cooling plate or forced-air cooling. (The cooling system shall be arranged by the customer.)
*4 Certified by Intertek for UL 1973, and by JET (Japan Electrical Safety & Environment Technology Laboratory) for JIS C 8715-2 and IEC62619.
*5 The certification applies at the component level only. Additional certification is required for the complete battery system.

Note: Specifications shown herein are not guaranteed values and are subject to change without notice. Battery performance depends on conditions of use.


Download

Toshiba Rechargeable Battery SCiB™

Technical Documents


Case Study